Application of Finite Element Modelling in the Qualification of Large diameter Unbonded Flexible Risers

Published: June 2002 | 21st International Conference on Offshore Mechanics and Arctic Engineering | June 23, 2002 | Oslo, Norway

Abstract

Unbonded flexible pipe has a proven track record in the offshore oil and gas industry for more than 20 years. The product is synonymous with the use of floating production systems spanning the water column and connecting subsea structures to facilitate the retrieval of hydrocarbons, provision of water injection systems and the export of processed or semi-processed fluids to main trunk pipelines or onshore. Unbonded Flexible pipe is a technically complex multi-layer structure of helically wound metallic wires and tapes and extruded thermoplastics.

In 1996 Wellstream was awarded a major contract for the supply of flexible risers and flowlines as part of the Norsk Hydro Troll Olje Gas Province Development located in 350m water depth 80km west of Bergen. The development consists of two main fields, Troll East (31/3 and 31/6) and Troll West (31/2) which together have an estimated production life in excess of 50 years, making it one of the worlds largest offshore developments. Norsk Hydro is responsible for the development and operation of the production facilities.

The scope of supply included 15-inch internal diameter, 213 barg design pressure, dynamic risers for the export of oil and gas from the platform to shore. At contract award, Wellstream was finalising the location of their European Manufacturing site, a facility which would have the capability of manufacturing unbonded flexible pipe with external diameters up to 24-inches.

The design, manufacture and qualification of a large diameter oil and gas export riser for service in the Norwegian sector of the North Sea, considered to be one of the most severe environments in the offshore industry, provided unique challenges and attributes. These risers have now been in service for over two year, following an extensive qualification programme. This paper provides an insight into the integrated approach adopted during qualification with the successful application of finite element technology to aid full-scale testing. During a full-scale test program a finite element simulation of a 15 metre long prototype pipe was performed with special emphasis on the evaluation of contact forces between the flexible pipe and a bend limiting structure. The finite element analysis program package ANSYS is chosen for this simulation due to its special feature of contact/target elements. The paper illustrates that the use of Finite Element Modelling is indeed capable of predicting the observed behaviour of prototype risers, which are subjected to a series of dynamic load cases, in a Dynamic Test Rig (DTR). Finally, the paper concludes that focus should now be given to the advantages of using finite element tools that are verified by full scale testing to reduce development costs and schedules.

 

Authors:

Zhang, Dr. W., Tuohy, J.

A Three-Dimensional Finite Element Analysis of Unburied Flexible Flowline – A Case Study

Published: June 2002 | 21st International Conference on Offshore Mechanics and Arctic Engineering | June 23, 2002 | Oslo, Norway

Abstract

Pipelines in the service of conveying hot fluid will tend to expand due to pressure and differential temperature. However, since the flowline is generally fixed at the end terminations to rigid structures or equipment, such an expansion will be restricted in longitudinal direction. This is particularly the case for the section remote from the pipe ends, and results in an axial compression in the pipe section. In many cases, a subsea flowline has to be trenched or buried for the purposes of protection and thermal insulation. Consequently, the lateral movement of a flexible flowline is greatly limited, and an upward displacement is encouraged that may become excessive. Eventually, the flowline may lift out of the trench when the uplift resistance provided by the backfill cover and self-weight of the flowline is gradually overcome by the strain energy built up in the flowline. For flexible pipe, it is this excessive upward deformation being termed as the Upheaval Buckling, which can be prevented by employing adequate downward restraint, such as sand bag / rock dump or by designing a subsea pipe route to overcome this phenomenon. In this paper a case study of the full three-dimensional finite element analysis of a trenched but unburied 6.0-inch production flowline is presented following a description of Wellstream Finite Element Method (FEM) based methodology for Upheaval Buckling analysis of flexible pipes. The effect Bending Stiffness Hysteresis and Upheaval Creep – unique to flexible pipe characteristics, is considered in addition to the general loads such as the flowline self-weight and backfill, pretension, pressure, temperature distribution and prescribed forces (either concentrated or distributed) and displacements. The effects of environmental loads, such as the action of currents that would result in scouring off the backfill, can also be addressed.
The finite element analysis program package ANSYS was chosen for this case study due to its special feature of ANSYS Parametric Design Language (APDL) and contact/target elements; and the general three-dimensional shell and solid elements were used to represent the flexible pipe and trench soil respectively.

 

Authors:

Zhang, Dr. W., Tuohy, J.